Electrical connection

Gas connection

The automatic ignition and the safety device require connect ion to an A.C. single phase 120 V, 60 Hz supply. Fuse rating 6 A.

The appliances are factory equipped with a power supply cord with molded three prong plug

ready for connection to an electrically grounded socket which complies with your local electrical codes or with the National Electrical Code ANSI/NFPA No. 70 for the USA or Electrical Code Part I for Canada.

Ensure that the receptacle is positioned so that it is easily accessible when the appliance is built in.

Check that the data given on the data plate under the appliance complies with the mains voltage.

Warning:

This appliance must be grounded.

Do not cut or remove the grounding prong from the plug.

12

These appliances must be installed with a separate shut-off valve and a gas pressure regulator.

Both shut-off valve and pressure regulator must be easily accessible to the consumer.

The shut-off valve is solely intended to be used to shut off the gas supply.

This appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system.

The hob comes equipped for natural gas.

You should find out details about the type of gas and calorific value from your Gas Utility and compare this information with the type of gas quoted on the data plate.

Before using the appliance, check the connection with a soapy solution for leaks. Never use a flame of any sort. The interior of this appliance has been tested by the manufacturer.

Pressure regulator

A pressure regulator is included with the appliance.

After installing a gas shut-off valve in an easily accessible location under the hob, install the gas pressure regulator to the manifold pipe using pipe dope on threads of the manifold pipe (see also next page).

Page 14
Image 14
Miele KM 326G manual Electrical connection, This appliance must be grounded