For Canada only
The gas connection must be made in accordance with the local codes, or in absence of local codes, with the current CAN/CA B 149.1 and .2 Inst.
Gas pressures for Canada
Manifold pressure:
–natural gas 4˝ water column
–liquid propane gas 10˝ water column
Nominal rating natural gas 4˝ 1)
Burner | high setting | low setting | ||
| kW | Btu/hr | kW | Btu/hr |
|
|
|
|
|
2.7 | 9200 | 0.35 | 1200 | |
super | 3.4 | 12000 | 0.45 | 1500 |
4.0 | 14000 | 0.17 | 580 | |
|
|
|
|
|
Nominal rating LP gas 10˝ with conversion kit 1)
Burner | high setting | low setting | ||
| kW | Btu/hr | kW | Btu/hr |
|
|
|
|
|
2.0 | 7000 | 0.40 | 1300 | |
super | 2.7 | 9200 | 0.50 | 2000 |
3.3 | 11200 | 0.18 | 600 | |
|
|
|
|
|
Important
a.The appliance and its individual
b.The appliance must be isolated from the gas supply piping system by closing its individual manual
Warning
The base of the hob will become hot. The gas connection used must comply with the relevant national and local regulations.
Important
When the gas hob has been installed, it is essential to check the main cable is not in contact with hot parts of the appliance, otherwise temperature damage to the cable could occur.
1)Important
This appliance with the orifices as delivered for natural gas or LP gas by the manufacturer is suitable for use till 2000 feet. By installation above 2000 feet contact your distributor or Miele USA/Canada and ask for a replacement set with orifices suitable for your altitude.
Change the orifices as written in the instructions of the manual.