Safety Instructions

Safety Instructions

Parts

Warning

This conversion kit must be installed by a qualified service agency.

This conversion kit is for use with Miele gas hob KM 326G only.

Conversion kit

type number AH 102 C4U

These conversion instructions are to be used together with the operating and installation instructions.

Right

Wrong

Check to ensure that the burner is burning correctly. The flames should be blue and uniform.

Right

Wrong

This conversion kit includes the following parts:

Part

ID number

Number

Burner cap

 

A

1

Injector wok burner

 

 

 

outer ring

 

090

1

Injector wok burner inner ring

007

1

Injector super high-speed

 

 

burner C

 

087

2

Injector high-speed burner B

075

2

Low flame screw outer

 

 

 

wok burner

 

054

1

Low flame screw inner

 

 

 

wok burner

 

025

1

Low flame screw burner C

040

2

Low flame screw burner B

036

2

Conversion instructions

Data plate LP gas 10” W.C.

Conversion data plate

This appliance is to be converted to Propane 10” W.C. (2.491 kPa) only.

Input ratings LP gas

. . . . . . . .high speed burner

7000

Btu/hr

super high speed burner

9200

Btu/hr

wok burner inner ring

1125

Btu/hr

wok burner outer ring

11200

Btu/hr

 

 

 

If the flames are not uniform, check to ensure that the burner cap is properly positioned on the ring.

If the flames are irregular and yellow, check to ensure that a pressure regulator has been

installed. Do not use the appliance and inform

the installer.