Miele KM 81-2 öInstructions for building-in, bAppliance cTensioning screw d Clamp

Models: KM 81-2

1 44
Download 44 pages 4.76 Kb
Page 27
Image 27
bAppliance

Instructions for building-in

 

 

Depth

Width *

 

 

in

(= Dimen-

 

 

inch

sion B)

 

 

 

in inch

 

 

 

2 zone Combiset

 

 

1

Combiset

19-5/16"

10-7/16"

2

Combisets

19-5/16"

22"

3

Combisets

19-5/16"

33-1/2"

4

Combisets

19-5/16"

45-1/32"

5

Combisets

19-5/16"

56-9/16"

 

 

 

4 zone Combiset

 

 

1

Combiset

19-5/16"

22"

2

Combisets

19-5/16"

45"

3

Combisets

19-5/16"

68"

Combination

 

 

One 2 zone

 

 

+ one 4 zone

19-5/16"

33-1/2"

Two 2 zone

 

 

+ one 4 zone

19-5/16"

45"

Three 2 zone

 

 

+ one 4 zone

19-5/16"

56-9/16"

One 2 zone

 

 

+ two 4 zone

19-5/16"

56-1/2"

Two 2 zone

 

 

+ two 4 zone

19-5/16"

68-1/16"

 

 

 

 

Extractor (e.g. DA 8-2)

For building in between two appliances: - Dimension B increases by 3 9/16".

For building in at the end of a combination:

-Dimension B increases by 3 7/8".

*Width includes provision for V 98 spacer bar.

Place the seal provided f under the edge of the cooktop.

loosen

tighten

bAppliance

cTensioning screw d Clamp

e Countertop f Seal

Turn the tensioning screws c in a - clockwise direction b until a resist- ance is felt, then turn the clamp to the left.

Place the appliance in position, turn the clamps and tighten the tension- ing screws until the clamps just touch the countertop e. Do not over- tighten.

Connect the appliance to the electri- cal supply.

When building-in several Combiset units, a stainless steel spacer bar (V 98 edge connector) must be installed be- tween each unit. It is supplied with its own installation instructions.

27

Page 27
Image 27
Miele KM 81-2 operating instructions öInstructions for building-in, bAppliance cTensioning screw d Clamp