]öConversion to alternative types of gas

Conversion to alternative types of gas

When converting to alternative types of gas (LP gas) or back to Natural gas, the main jet and the small jets of the burner must be changed.

Turn off the gas main (if this ap- pliance has already been installed), turn off the electrical supply and pull out the plug.

Remove the wok/pan support, the large burner cap, the burner ring and the large burner cap base.

With a philipeshead screwdriver, loosen the three screws.

Pull the controls for the gas burner up and off.

Carefully raise the cooktop cover slightly at the rear and pull forward. Then carefully lift upwards and for- wards. Ensure that the ground lead which connects the cooktop and the control panel is not damaged.

Screw in the new jets following the table. The gas cooktop unit is sup- plied ready equipped for natural gas; the appropriate gas jet kit for cy- linder gas, LPG (Liquefied Petro- leum), is supplied with the appliance.

Reference table - jet sizes

USA/CDN

gas type

burner size

jet

adj.

 

 

 

screw

 

 

 

 

Natural

Small

No. 34

0.40 mm

 

Large

2.0 mm

0.88 mm

 

 

 

 

Propane

Small

No. 7

0.25 mm

 

Large

1.20 mm

0.54 mm

 

 

 

 