For your safety

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other ap- pliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas sup- plier from a neighbor’s phone. Follow the gas supplier’s instruc- tions.

If you cannot reach your gas sup- plier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Note to the installer (CDN and USA)

LEAVE THESE INSTRUCTIONS WITH THE CONSUMER.

The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).

For Canada only:

The minimum supply pressure for checking the regulator setting shall be 5 inches water column (1246 Pa), which is 1 inch water column (249 Pa) above the manifold pressure of 4 in- ches water column (996 Pa).

Instructions for replacement of fixed ori- fices are shown on page 32. Save the orifices removed from the appliance for future use.

5

Page 5
Image 5
Miele KM 81-2 operating instructions For your safety, For Canada only