@äElectrical connection
Electrical connection AUS
Electrical connection of the appliance should be undertaken by a suitably competent person in strict accordance with national and local safety regula- tions.
For extra safety it is advisable to install a residual current device (RCD), with a trip current of 30 mA.
The appliances are supplied with a mains cable for connection to single phase 240 V, 50 Hz supply. The plug rating and rated load are given on the data plate.
Connection should be made by a switched socket. The
Electrical connection NZ
The appliances are supplied with a mains cable for connection to single phase 230 V, 50 Hz supply. The plug rating and rated load are given on the data plate.
Important:
The wires in the mains lead are col- oured in accordance with the following code:
Green/yellow = earth
Blue = neutral
Brown = live
As the colours of the wires in the mains lead of this appliance may not corre- spond with the coloured markings ident- ifying the terminals in your plug, pro- ceed as follows:
The wire which is coloured green and yellow must be connected to the termi- nal in the plug which is marked with the letter E or by the earth symbol z or col- oured green or green and yellow.
The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.
The wire which is coloured brown must be connected to the terminal which is marked with the letter A or coloured red.
WARNING
THIS APPLIANCE MUST BE
EARTHED.
Technical data AUS (NZ)
Total connected load . . . . . . . . . . . 25 W
Electrical connection:
. . . . . . . . . . . . . . 50 Hz, 240 V (230 V)
Plug rating . . . . . . . . . . . . . . . . . . . 10 A
Connection cable . . . . . . . . . . . 1.10 m
If the connection cable needs replac-
ing, only use cable with at least 3 x 1 mm2.
19