4-10. Display Board (PC20) DIP Switch Settings

1

2

3

4

5

DIP Switch Settings:

Display Hold ON

Displays will hold their last value for five seconds after the trigger is re- leased. After the hold times out, the Voltage Display will show open circuit voltage. If the Wire Speed / Amps Display is set to display Amps, the amperage value will hold, after the hold times out, preset Wire Speed will be displayed.

 

 

 

 

 

Display Hold OFF

 

 

 

 

 

Displays will not hold values. Immedi-

1

2

3

4

5

ately, when the trigger is released,

the Voltage Display will show open

 

 

 

 

 

 

 

 

 

 

circuit voltage. The Wire Speed /

 

 

 

 

 

Amps Display will display preset Wire

 

 

 

 

 

Speed when the trigger is released.

1

 

2

 

3

 

4

 

5

DIP Switch Factory Settings

Indicates Switch does not Affect This Function

1

2

3

4

5

1

2

3

4

5

Do Not Display Amperage

Wire Speed / Amps Display will dis- play only Wire Speed.

Display Amperage

Wire Speed / Amps Display will dis- play Amps while welding and Wire Speed while not welding. If the hold function is enabled, Amps will be dis- played during hold also.

.DIP switch is located

behind front panel as shown.

1

2

3

4

5

1

2

3

4

5

1

2

3

4

5

1

2

3

4

5

Ref. 804 006-A

Wire Speed - Inches Per Minute

Displays Wire Speed in Inches per Minute.

Wire Speed - Meters Per Minute

Displays Wire Speed in Meters per Minute.

Information OFF

Information is not displayed.

Information ON

With switch in ON position, at feeder power up, feeder will display various sets of information. Each set of infor- mation will be displayed for three sec- onds.

Display Board (PC20) Software Part Number −

Top display will show the first three digits, bottom display will show last three digits of the Display board (PC20) software revision level.

Motor Board (PC1) Software Part Number −

Top display will show the first three digits, bottom display will show last three digits, of the Motor board (PC1) software revision level.

Accumulated Weld Time −

This is the time the feeder has actual- ly been used for welding. This infor- mation will be displayed in two halves. First being years and days, second in hours and minutes. Top display will show years/hours, bot- tom display will show days/minutes.

OM-1500-19 Page 20

Page 24
Image 24
Miller Electric 12VS manual Display Board PC20 DIP Switch Settings