4-10. Display Board (PC20) DIP Switch Settings
1 | 2 | 3 | 4 | 5 |
DIP Switch Settings:
Display Hold ON
Displays will hold their last value for five seconds after the trigger is re- leased. After the hold times out, the Voltage Display will show open circuit voltage. If the Wire Speed / Amps Display is set to display Amps, the amperage value will hold, after the hold times out, preset Wire Speed will be displayed.
|
|
|
|
| Display Hold OFF | |
|
|
|
|
| Displays will not hold values. Immedi- | |
1 | 2 | 3 | 4 | 5 | ately, when the trigger is released, | |
the Voltage Display will show open | ||||||
|
|
|
|
| ||
|
|
|
|
| circuit voltage. The Wire Speed / | |
|
|
|
|
| Amps Display will display preset Wire | |
|
|
|
|
| Speed when the trigger is released. |
1 |
| 2 |
| 3 |
| 4 |
| 5 |
DIP Switch Factory Settings
Indicates Switch does not Affect This Function
1 | 2 | 3 | 4 | 5 |
1 | 2 | 3 | 4 | 5 |
Do Not Display Amperage
Wire Speed / Amps Display will dis- play only Wire Speed.
Display Amperage
Wire Speed / Amps Display will dis- play Amps while welding and Wire Speed while not welding. If the hold function is enabled, Amps will be dis- played during hold also.
.DIP switch is located
behind front panel as shown.
1 | 2 | 3 | 4 | 5 |
1 | 2 | 3 | 4 | 5 |
1 | 2 | 3 | 4 | 5 |
1 | 2 | 3 | 4 | 5 |
Ref. 804
Wire Speed - Inches Per Minute
Displays Wire Speed in Inches per Minute.
Wire Speed - Meters Per Minute
Displays Wire Speed in Meters per Minute.
Information OFF
Information is not displayed.
Information ON
With switch in ON position, at feeder power up, feeder will display various sets of information. Each set of infor- mation will be displayed for three sec- onds.
Display Board (PC20) Software Part Number −
Top display will show the first three digits, bottom display will show last three digits of the Display board (PC20) software revision level.
Motor Board (PC1) Software Part Number −
Top display will show the first three digits, bottom display will show last three digits, of the Motor board (PC1) software revision level.
Accumulated Weld Time −
This is the time the feeder has actual- ly been used for welding. This infor- mation will be displayed in two halves. First being years and days, second in hours and minutes. Top display will show years/hours, bot- tom display will show days/minutes.