Page 22
Image 22

. Complete Parts List available at www.MillerWelds.com

5-2. Grounding Generator When Supplying Building Systems

1 2

GND/PE

23

Ground generator to system earth ground if supplying power to a premises (home, shop, farm) wiring system.

1Equipment Grounding Terminal

2Grounding Cable

Use #10 AWG or larger insulated copper wire.

3 Ground Device

.Use ground device as stated in electrical codes.

800 576-B

5-3. Engine Prestart Checks − Standard Model

1/2 in

 

(13 mm)

Full

 

Gasoline

 

1

Check all fluids daily. Engine must be cold and on a level surface. Unit is shipped with 10W30 engine oil.

1Fuel Valve Open valve.

.Fuel valve is shown in the open

position. Always close fuel valve after stopping unit. Mov- ing unit with fuel valve open may cause carburetor flooding and make starting difficult.

Fuel

Add fresh fuel before starting engine the first time (see engine manual for specifications). Fill fuel tank up to 1/2 in. (13 mm) from top to allow room for expansion. Check fuel level on a cold engine before use each day.

Oil

After fueling, check oil with unit on level surface. If oil is not up to full mark on dipstick, add oil (see en- gine manual).

Unit stops if oil level is too low. Unit cannot be restarted until sufficient oil is added.

Full

Ref. 803 597−B / Ref. 802 099

OM-4415 Page 18

Page 22
Image 22