Miller Electric 185 DX manual Connecting To Weld Output Terminals, Selecting Weld Cable Sizes

Models: 185 DX 185

1 56
Download 56 pages 59.71 Kb
Page 24
Image 24

5-6. Connecting To Weld Output Terminals

2

6

3

Do not place anything between weld cable terminal and copper bar.

4

5

.Complete Parts List available at www.MillerWelds.com

1Positive (+) Weld Output Terminal

2Negative (−) Weld Output Terminal

For Direct Current Electrode Posi- tive (DCEP), connect work cable to

1Negative (−) terminal and electrode holder to Positive (+) terminal.

For Direct Current Electrode nega- tive (DCEN), reverse cable con- nections.

Failure to properly connect weld cables may cause excessive heat and start a fire, or damage your machine.

3Weld Output Terminal

4Supplied Weld Output Terminal Nut

5Weld Cable Terminal

6Copper Bar

Remove supplied nut from weld output terminal. Slide weld cable terminal onto weld output terminal and secure with nut so that weld cable terminal is tight against cop- per bar. Do not place anything between weld cable terminal and copper bar. Make sure that the surfaces of the weld cable terminal and copper bar are clean.

Tools Needed: 3/4 in

Correct Installation

Incorrect Installation

803 596−B / 803 778-A

5-7. Selecting Weld Cable Sizes*

Weld Output

Terminals

Stop engine before connecting to weld output terminals.

Do not use worn, dam- aged, undersized, or poorly spliced cables.

 

Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit

 

 

 

Not Exceeding***

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100 ft (30 m) or Less

150 ft

200 ft

250 ft

300 ft

 

350 ft

400 ft

 

(45 m)

(60 m)

(70 m)

(90 m)

 

(105 m)

(120 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Welding

10 − 60%

60 − 100%

 

 

 

 

 

 

 

Duty

Duty

 

10 − 100% Duty Cycle

 

 

Amperes

 

 

 

Cycle

Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

4 (20)

4 (20)

4 (20)

3 (30)

2 (35)

1 (50)

 

1/0 (60)

1/0 (60)

 

 

 

 

 

 

 

 

 

 

150

3 (30)

3 (30)

2 (35)

1 (50)

1/0 (60)

2/0 (70)

 

3/0 (95)

3/0 (95)

 

 

 

 

 

 

 

 

 

 

200

3 (30)

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

 

4/0 (120)

4/0 (120)

 

 

 

 

 

 

 

 

 

 

250

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120)

 

2 ea. 2/0

2 ea. 2/0

 

(2x70)

(2x70)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120)

2 ea. 2/0

 

2 ea. 3/0

2 ea. 3/0

(2x70)

 

(2x95)

(2x95)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*This chart is a general guideline and may not suit all applications. If cables overheat, use next size larger cable.

**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.

( ) = mm2 for metric useS-0007-F

***For distances longer than those shown in this guide, call a factory applications representative at 920-735-4505.

OM-4415 Page 20

Page 24
Image 24
Miller Electric 185 DX manual Connecting To Weld Output Terminals, Selecting Weld Cable Sizes, 150 ft 200 ft 250 ft