SECTION 8 − MAINTENANCE

.Follow the storage procedure in the engine owner’s manual if the unit will not be used for an extended period.

8-1. Routine Maintenance

 

 

 

 

Stop engine before maintaining.

 

 

 

Recycle engine

. See Engine Manual and Maintenance Label

 

 

 

fluids.

for important start-up, service, and storage

 

 

 

information. Service engine more often if

 

 

 

 

used in severe conditions.

n = Check

Z = Change

~ = Clean

l = Replace

Reference

* To be done by Factory Authorized Service Agent

 

 

Every

 

 

Section 5-3,

8

 

 

5-4

Hours

 

 

 

n Fuel Level

n Oil Level

~ Oil, Fuel Spills

 

Every

 

 

Section 8-2

25

 

 

 

Hours

 

 

 

~ Air Cleaner Precleaner

 

 

 

Every

 

 

 

50

 

 

 

Hours

 

 

 

~ Weld Terminals

 

 

 

Every

 

 

Engine

100

 

 

Manual,

Hours

 

 

Section 8-2

Z Oil

nl Air Cleaner Element

~ Cooling System

n Spark Plug Gap

~ Battery Terminals (DX

n~ Spark Arrestor Screen

 

 

Models)

(Optional on DX Models)

 

 

Every

 

 

 

200

 

 

 

Hours

 

 

 

l Unreadable Labels

 

 

 

Every

 

 

Engine

300

 

 

Manual

Hours

 

 

 

nValve Clearance*

 

 

 

Every

 

 

Engine

500

 

 

Manual

Hours

 

 

 

nl Weld Cables

n~ Slip Rings*

 

 

 

nl Brushes*

 

 

 

 

 