Miller Electric Big Blue 400 PX manual Activating The Dry Charge Battery If Applicable

Models: Big Blue 400 PX

1 76
Download 76 pages 53.58 Kb
Page 29
Image 29

5-4. Activating The Dry Charge Battery (If Applicable)

 

! Always wear a face shield,

 

rubber gloves and protective

 

clothing when working on a

3

battery.

 

 

Remove battery from unit.

 

5

Vent Caps

2

6

Sulfuric Acid Electrolyte

 

 

(1.265 Specific Gravity)

1

7

Well

Fill each cell with electrolyte to bottom of well (maximum).

! Do not overfill battery cells.

Wait ten minutes and check electro- lyte level. If necessary, add electro- lyte to raise to proper level. Reins- tall vent caps.

8 Battery Charger

! Read and follow all instruc- tions supplied with battery charger.

4

5 A For 30 Minutes

OR+

Tools Needed:

30 A For 12 Minutes

 

Charge battery for 12 minutes at 30 amperes or 30 minutes at 5 am- peres. Disconnect charging cables and install battery.

.When electrolyte is low, add

only distilled water to cells to maintain proper level.

drybatt1 6/05 − S-0886

5-5. Connecting The Battery

. Close door after connecting battery.

. The engine will not run if engine access door is open.

! Connect Negative (−) Cable Last.

+

Tools Needed:

1/2 in

Ref. 804 009 / Ref. 222 875 / S-0756-C

 

OM-223 037 Page 23

Page 29
Image 29
Miller Electric Big Blue 400 PX manual Activating The Dry Charge Battery If Applicable, Connecting The Battery