8-9. Overload Protection
3
! Stop engine.
. When a supplementary protec- tor, circuit breaker or fuse opens, it usually indicates a more serious problem exists. Contact Factory Authorized Service Agent.
| 1 | Fuse F1 |
| F1 | protects the stator exciter wind- |
| ing from overload. If F1 opens, weld | |
| and generator power is low or stops | |
| entirely. | |
| 2 Circuit Breaker CB1 (Not | |
|
| Shown) |
| 3 | Supplementary Protector CB2 |
| 4 | Supplementary Protector CB3 |
| 5 | Supplementary Protector CB8 |
| CB1 protects the engine battery cir- | |
| cuit. If CB1 opens, the engine will not | |
| crank. CB1 automatically resets | |
| when the fault is corrected. | |
| CB2 protects the engine wiring har- | |
| ness. If CB2 opens, the engine will | |
| not crank. | |
| CB3 protects part of the weld control | |
| wiring harness. If CB3 opens, weld | |
| and generator power output stops. | |
| CB8 protects the 24 volt ac output to | |
| remote receptacle RC14. If CB8 | |
| opens, 24 volt output to RC14 stops. | |
| Press button to reset supplementary | |
1 | protector. |
4
5
Ref. 222