4-7. Remote 14 Receptacle RC3 Information
A | J | |
B | K | I |
|
| |
C | L N | H |
D | M | G |
| E | F |
OR
Ref.
| Socket* | Socket Information | |
| A | 24 volts ac. Protected by circuit | |
|
| breaker CB4. | |
| B | Contact closure to A completes 24 | |
|
| volts ac contactor control circuit. | |
| I | 115 volts ac. Protected by circuit | |
|
| breaker CB3. | |
| J | Contact closure to I completes 115 | |
|
| volts ac contactor control circuit. | |
| G | Circuit common for 24 and 115 | |
|
| volts ac circuits. | |
| C | 0 to +10 volts dc output to remote | |
|
| control from min to max of Amper- | |
|
| age/Voltage control R1. | |
A/V | D | Remote control circuit common. | |
E | 0 to +10 volts dc input command | ||
| |||
|
| signal from remote control. | |
| K | Chassis common. |