Image 24

6-2. 240 Volt Duplex Receptacle (Optional)

1

3

2

YIf unit does not have GFCI recep- tacles, use GFCI-protected exten- sion cord.

1240 V 15 A AC Duplex Receptacle RC1

Receptacle supplies 60 Hz single-phase power at weld/power speed. Maximum out- put from this receptacle is 3 kVA/kW.

 

 

 

 

 

Ref. ST-174 733 / ST-174 757

2 120 V 20 A AC Duplex Receptacle

 

 

 

4

. If a circuit breaker continues to open,

GFCI2 (Section 6-1)

 

 

contact a Factory Authorized Service

 

 

 

 

3 Circuit Breakers CB1 And CB2

 

 

Agent.

 

 

4 Total Generator Power Output

 

 

 

 

CB1 and CB2 protect the 120 V and 240 V

 

 

Combined output of all receptacles limited

 

 

to 3 kVA/kW output of the generator.

receptacles from overload. If CB1 or CB2

 

 

 

 

EXAMPLE: If 10 A is drawn from the 240 V

opens, the 240 V receptacle and one half of

 

 

 

 

receptacle, only 5 A is available at the 120

the 120 V receptacle does not work. 120

 

 

 

 

V receptacle:

volts may still be present at the 240 volt re-

 

 

 

 

 

 

ceptacle. Press button to reset breaker.

 

 

(240 V x 10 A) + (120 V x 5 A) = 3.0 kVA/kW

SECTION 7 – MAINTENANCE & TROUBLESHOOTING

7-1. Routine Maintenance

Note

Follow the storage procedure in the engine owner’s manual if the unit will not be used for an

 

extended period.

Recycle engine

fluids.

YStop engine before maintaining.

.See also Engine Manual and Mainte- nance Label. Service engine more often if used in severe conditions.

*To be done by Factory Authorized Service Agent.

8 h

Wipe

Up

Spills.

OIL

Full

Check Fluid

FUEL

Drain Water

Levels. See

WATER

From Fuel

Section 4-4.

 

System.

50 h

Clean Air Filter. See Section 7-3.

Clean And

Tighten

Weld

Terminals.

OM-481 Page 20