Miller Electric Big Blue 600D manual Adjusting Overspeed Shutdown Valve

Models: Big Blue 600D

1 60
Download 60 pages 53.61 Kb
Page 31
Image 31

7-9. Adjusting Overspeed Shutdown Valve

OFF

YStop engine, and let cool.

The overspeed shutdown valve protects the engine from damage

10 9 8

2

3

RUN

START

due to high engine speed. If the en- gine stops, the valve may be closed.

Shutdown speed is between 1950 and 2100 rpm. Use a tachometer to check shutdown speed as follows:

Open right side door and remove rear panel.

1Air Cleaner

2Hose Into Air Cleaner

3Hose Clamp

Loosen clamp and remove hose.

4Plastic Cap

5High Speed Stop Screw

6Lock Nut

1

Engine End

Drawing #

7

6

5

4

Tools Needed:

3/8 in

Remove plastic cap from screw. Loosen nut. Turn screw out (toward front of engine) several turns.

7Speed Control Lever

8Overspeed Shutdown Valve

Start engine and increase speed by moving lever toward high speed stop screw. Note engine rpm when valve closes and stops engine.

If shutdown speed is not between 1950 and 2100 rpm, adjust as follows:

9Lock Nut

10Valve Adjustment Screw

Loosen nut and turn screw one turn (clockwise to increase and counter- clockwise to decrease shutdown rpm). Tighten nut.

Check shutdown speed and repeat adjustment if needed.

YStop engine.

Turn high speed stop screw in until screw touches lever. Tighten lock nut on screw and reinstall plastic cap.

Install hose and hose clamp. Install rear panel and close side door.

If necessary, adjust engine speed according to Section 7-5

OM-481 Page 27

Page 31
Image 31
Miller Electric Big Blue 600D manual Adjusting Overspeed Shutdown Valve, Speed Control Lever Overspeed Shutdown Valve