Miller Electric CST 250 VRD manual Installation, Specifications, Duty Cycle And Overheating

Models: CST 250 VRD

1 44
Download 44 pages 34.31 Kb
Page 13
Image 13

SECTION 3 − INSTALLATION

3-1. Specifications

Welding

Input

Rated

Welding

Maximum

Amperes Input At Rated Load

 

 

 

Net

Mode

Power

Output

Amperage

Open-Circuit

 

Output, 50/60 Hz

 

KVA

KW

Dimensions

 

 

 

Range

Voltage

 

 

 

 

 

Weight

 

 

 

220

 

400

 

440

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

250 A @

 

 

 

 

 

 

 

 

 

 

 

 

 

30 VDC,

 

 

32.1

 

18.2

 

16.4

12.3

8.7

 

 

 

 

50 % Duty

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-Phase

Cycle

5-250 A

30 VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200 A @

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28 VDC,

 

 

24.2

 

14.4

 

12.6

9.9

6.5

H: 13-1/2 in

 

 

 

100 %

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(343 mm)

 

Stick

 

Duty Cycle

 

 

 

 

 

 

 

 

 

40 lb

 

 

 

 

 

 

 

 

 

 

W: 7-1/2 in

 

 

 

 

 

 

 

 

 

 

 

(SMAW)

 

 

 

 

 

 

 

 

 

 

 

(191 mm)

(18.2 kg)

 

200 A @

 

 

 

 

 

 

 

 

 

 

 

28 VDC,

 

 

42.6

 

n/a

 

n/a

10.0

6.6

D: 18 in (457

 

 

 

50 % Duty

 

 

 

 

mm)

 

 

1-Phase

Cycle

5-200 A

30 VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150 A @

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26 VDC,

 

 

33.6

 

n/a

 

n/a

7.4

5.7

 

 

 

 

100 %

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Duty Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-2. Duty Cycle And Overheating

Duty Cycle is percentage of 10 minutes that unit can weld at rated load without overheating.

If unit overheats, output stops, and cooling fan runs. Wait fifteen minutes for unit to cool. Reduce amperage or duty cycle before welding.

Y Exceeding duty cycle can damage unit and void warranty.

206 173

200 A @ 50% Duty Cycle For Single Phase Operation

250 A @ 50% Duty Cycle For 3 Phase Operation

5 Minutes Welding

5 Minutes Resting

5 Minutes Welding

5 Minutes Resting

Overheating

 

 

 

 

0

A or V

 

 

 

15

 

 

 

OR

 

 

Minutes

Reduce Duty Cycle

 

 

 

 

OM-220 812 Page 9

Page 13
Image 13
Miller Electric CST 250 VRD manual Installation, Specifications, Duty Cycle And Overheating