Miller Electric CST 250 VRD manual Selecting 220 Volts AC Single/Three Phase Input Voltage

Models: CST 250 VRD

1 44
Download 44 pages 34.31 Kb
Page 20
Image 20

3-10. Selecting 220 Volts AC Single/Three Phase Input Voltage

1

2

34

Tools Needed:

5/16 in

YTurn Off welding power source, and disconnect

input power before proceeding.

Check input voltage available at site.

1Voltage Selection View Window

The input voltage that the power source is linked for appears in the Voltage Selection View Window.

Check voltage selected in unit. Changing selection is only necessary if selected value does not match available input voltage.

To change relinking board position, remove top cover and left side panel.

2Relinking Board

3Terminal Screws Loosen terminal screws.

4Relinking Board (Connection For 220 VAC Single/Three Phase Input Power)

Slide relinking board off connected terminals, move relinking board to correct input voltage terminals, and secure relinking board.

.Be sure to tighten all four screws securing relinking board in place.

803 079 / 803 077

OM-220 812 Page 16

Page 20
Image 20
Miller Electric CST 250 VRD manual Selecting 220 Volts AC Single/Three Phase Input Voltage