3-12. Connecting Input Power

Green Or

Green/Yellow

3

1

 

2

 

L1

 

L2

L1

L3

L2

 

Green Or

Green/Yellow

YAlways connect grounding conductor first

=GND/PE 1

1

Green or

Green/Yellow

6

1

YDisconnect and lockout/tag- out input power before connecting input conduc- tors from unit.

YHave only qualified persons make this installation.

See rating label on unit and check input voltage available at site.

1Input And Grounding Conductors

2Line Disconnect Device See Section 3-9.

For three-phase operation:

YAlways connect green or green/yellow wire to supply grounding terminal, never to a line terminal.

2Connect black, white, and red wires (L1, L2, L3) to line terminals.

For single-phase operation:

YAlways connect green or green/yellow wire to supply grounding terminal, never to a line terminal.

3Black And White Input Conductor

4Red Input Conductor

5Insulation Sleeving

6Electrical Tape

Insulate and isolate red conductor as shown.

3

4

5

input_2 3/96 - 803 080

OM-220 812 Page 18

Page 22
Image 22
Miller Electric CST 250 VRD manual Connecting Input Power, For three-phase operation, For single-phase operation, = Gnd/Pe