3-6. Weld Output Terminals And Selecting Cable Sizes*

 

 

Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit

 

 

 

 

 

Not Exceeding

 

 

 

 

 

100 ft (30 m) Or Less

150 ft

200 ft

250 ft

300 ft

350 ft

400 ft

 

 

(45 m)

(60 m)

(70 m)

(90 m)

(105 m)

(120 m)

 

 

 

 

Weld Output

Welding

10 − 60%

60 − 100%

 

 

 

 

 

 

Duty

Duty

 

 

10 − 100% Duty Cycle

 

Terminals

Amperes***

 

 

 

Cycle

Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

4 (20)

4 (20)

4 (20)

3 (30)

2 (35)

1 (50)

1/0 (60)

1/0 (60)

 

150

3 (30)

3 (30)

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95

3/0 (95)

 

200

3 (30)

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120)

4/0 (120)

 

250

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120)

2 ea. 2/0

2 ea. 2/0

 

(2x70)

(2x70)

 

 

 

 

 

 

 

 

+

300

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120)

2 ea. 2/0

2 ea. 3/0

2 ea. 3/0

Output Receptacles

 

 

 

 

 

 

(2x70)

(2x95)

(2x95)

*This chart is a general guideline and may not suit all applications. If cable overheating occurs (normally you can smell it), use next size larger cable.

**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.

( ) = mm2 for metric use

 

***Select weld cable size for pulsing application at peak amperage value.

S-0007-E−803 080

OM-220 812 Page 13

Page 17
Image 17
Miller Electric CST 250 VRD manual Weld Output Terminals And Selecting Cable Sizes, 150 ft 200 ft 250 ft, Terminals Amperes