3-7. Weld Cable Size*
|
| Total Cable (Copper) Length In Weld Circuit Not Exceeding |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
| 100 ft (30 m) Or Less | 150 ft | 200 ft |
| 250 ft | 300 ft |
| 350 ft | 400 ft | |
| (45 m) | (60 m) |
| (70 m) | (90 m) |
| (105 m) | (120 m) | ||
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
Welding | 10 To 60% | 60 Thru 100% |
|
| 10 Thru 100% Duty Cycle |
|
| |||
Amperes | Duty Cycle | Duty Cycle |
|
|
|
| ||||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |
100 | 4 | 4 | 4 | 3 |
| 2 | 1 |
| 1/0 | 1/0 |
150 | 3 | 3 | 2 | 1 |
| 1/0 | 2/0 |
| 3/0 | 3/0 |
200 | 3 | 2 | 1 | 1/0 |
| 2/0 | 3/0 |
| 4/0 | 4/0 |
250 | 2 | 1 | 1/0 | 2/0 |
| 3/0 | 4/0 |
| ||
300 | 1 | 1/0 | 2/0 | 3/0 |
| 4/0 |
| |||
350 | 1/0 | 2/0 | 3/0 | 4/0 |
|
| ||||
400 | 1/0 | 2/0 | 3/0 | 4/0 |
|
| ||||
500 | 2/0 | 3/0 | 4/0 |
|
| |||||
600 | 3/0 | 4/0 |
|
| ||||||
700 | 4/0 |
|
| |||||||
800 | 4/0 |
|
| |||||||
|
|
|
|
|
|
|
|
| ||
*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. |
3-8. Optional Remote Receptacle Information And Connections
1 Remote Receptacle
Single models have one Remote receptacle RC3. Dual models have two Remote receptacles RC3 and RC4.
2 Keyway
3 Remote Grid Amperage
Control
4 Plug PLG1
5 Threaded Collar
To connect to this receptacle, align keyway, insert plug, and tighten threaded collar.
3 | 4 |
|
5
REMOTE
|
| 2 |
A | H | 1 |
B | K | G |
C | M | F |
|
| |
D | E |
|
sb7.1 8/92* – Ref.