3-7. Weld Cable Size*

 

 

Total Cable (Copper) Length In Weld Circuit Not Exceeding

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100 ft (30 m) Or Less

150 ft

200 ft

 

250 ft

300 ft

 

350 ft

400 ft

 

(45 m)

(60 m)

 

(70 m)

(90 m)

 

(105 m)

(120 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Welding

10 To 60%

60 Thru 100%

 

 

10 Thru 100% Duty Cycle

 

 

Amperes

Duty Cycle

Duty Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

4

4

4

3

 

2

1

 

1/0

1/0

150

3

3

2

1

 

1/0

2/0

 

3/0

3/0

200

3

2

1

1/0

 

2/0

3/0

 

4/0

4/0

250

2

1

1/0

2/0

 

3/0

4/0

 

2-2/0

2-2/0

300

1

1/0

2/0

3/0

 

4/0

2-2/0

 

2-3/0

2-3/0

350

1/0

2/0

3/0

4/0

 

2-2/0

2-3/0

 

2-3/0

2-4/0

400

1/0

2/0

3/0

4/0

 

2-2/0

2-3/0

 

2-4/0

2-4/0

500

2/0

3/0

4/0

2-2/0

 

2-3/0

2-4/0

 

3-3/0

3-3/0

600

3/0

4/0

2-2/0

2-3/0

 

2-4/0

3-3/0

 

3-4/0

3-4/0

700

4/0

2-2/0

2-3/0

2-4/0

 

3-3/0

3-4/0

 

3-4/0

4-4/0

800

4/0

2-2/0

2-3/0

2-4/0

 

3-4/0

3-4/0

 

4-4/0

4-4/0

 

 

 

 

 

 

 

 

 

*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.

S-0007-D

3-8. Optional Remote Receptacle Information And Connections

1 Remote Receptacle

Single models have one Remote receptacle RC3. Dual models have two Remote receptacles RC3 and RC4.

2 Keyway

3 Remote Grid Amperage

Control

4 Plug PLG1

5 Threaded Collar

To connect to this receptacle, align keyway, insert plug, and tighten threaded collar.

3

4

 

5

REMOTE

 

 

2

A

H

1

B

K

G

C

M

F

 

 

D

E

 