Chapter | 6 |
| Diagnosing Problems |
|
| ||
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
| Table 15. LCD Message Troubleshooting Table (continued) |
| |||||
|
|
|
|
|
| ||
COIL HOT |
| Yes | One or more hammer coils | Check printer environment. If too |
| ||
|
|
|
|
| are hot. | hot or dusty, relocate printer. May |
|
|
|
|
|
|
| occur normally on graphically |
|
|
|
|
|
|
| intense print jobs. |
|
|
|
|
|
|
| ||
CTL VOLT FAIL* |
| No | Controller voltage failure. | Contact your authorized service |
| ||
|
|
|
|
|
| representative.1 |
|
|
|
|
|
|
| ||
DRVR CIR BAD* |
| No | Hammer coil count test | Contact your authorized service |
| ||
|
|
|
|
| failed. | representative.1 |
|
|
|
|
|
|
| ||
EXHAUST FAN FLT |
| Yes | Sensors cannot detect | Power off the printer and remove |
| ||
(Cabinet model only) |
|
| current in fan circuit. | the paper path (see Maintenance |
| ||
|
|
|
|
|
| Manual). Check that the fan |
|
|
|
|
|
|
| cable connector is connected. |
|
|
|
|
|
|
| Check for obstruction of vents |
|
|
|
|
|
|
| and fan airway, and remove any |
|
|
|
|
|
|
| obstructions. Check for items |
|
|
|
|
|
|
| beneath the printer blocking |
|
|
|
|
|
|
| cabinet vents. Power back on the |
|
|
|
|
|
|
| printer. If this message recurs, |
|
|
|
|
|
|
| contact your authorized service |
|
|
|
|
|
|
| representative.1 |
|
|
|
|
|
|
| ||
FIRMWARE ERROR* |
| No | Application software tried to | Contact your authorized service |
| ||
|
|
|
|
| perform an illegal printer | representative.1 |
|
|
|
|
|
| function or damaged |
|
|
|
|
|
|
| memory detected on board. |
|
|
|
|
|
|
|
| ||
FRAMING ERROR |
| Yes | Serial framing error (serial | Check your serial host interface |
| ||
|
|
|
|
| interface). | parameter settings; if necessary, |
|
|
|
|
|
|
| adjust them so that they match |
|
|
|
|
|
|
| the settings of the attached host. |
|
|
|
|
|
|
| ||
HAM. COIL OPEN* |
| No | Electrical malfunction of one | Contact your authorized service |
| ||
|
|
|
|
| or more hammer coils. | representative.1 |
|
|
|
|
|
|
| ||
HAMMER COIL BAD* |
| No | Hammer coil # failed current | Contact your authorized service |
| ||
#, #, # |
|
|
|
| test at power up. | representative.1 |
|
|
|
|
|
|
|
|
|
202