| Fault Messages |
|
|
|
|
|
|
Table 15. LCD Message Troubleshooting Table (continued) |
| |||
|
|
|
|
|
HMR BANK FAN FLT | Yes | Sensors cannot detect | Check that fan cable is |
|
|
| current in fan circuit. | connected. Check for obstruction |
|
|
|
| of vents and fan airway; remove |
|
|
|
| any obstructions. Check for items |
|
|
|
| beneath the printer blocking |
|
|
|
| cabinet vents. Power back on the |
|
|
|
| printer. If this message recurs, |
|
|
|
| contact your authorized service |
|
|
|
| representative.1 |
|
|
|
|
|
|
HB NOT INSTALLD* | No | Contact your authorized service |
| |
|
| hammer coils. | representative.1 |
|
|
|
|
|
|
ILL EXT BUS ACC* | No | Fatal firmware error on | Contact your authorized service |
|
|
| controller board. | representative.1 |
|
|
|
|
|
|
ILLGL OPR ACCSS* | No | Fatal firmware error on | Contact your authorized service |
|
|
| controller board. | representative.1 |
|
|
|
|
|
|
ILL INST ACCSS* | No | Fatal firmware error on | Contact your authorized service |
|
|
| controller board. | representative.1 |
|
|
|
|
|
|
INTAKE FAN FAULT | Yes | Sensors cannot detect | See description for |
|
|
| current in fan circuit. | HMR BANK FAN FLT. |
|
|
|
|
|
|
LO DRV. SHORT * | No | Circuit(s) on the hammer | Contact your authorized service |
|
|
| bank or in the hammer bank | representative.1 |
|
|
| power cable shorted to |
|
|
|
| ground. |
|
|
|
|
|
|
|
LOAD PAPER | Yes | Printer is out of paper. | Load paper. |
|
|
|
|
|
|
ONLINE | No | Contact your authorized service |
| |
8344 FAILED* |
| hardware failure. | representative.1 |
|
|
|
|
|
|
PAP BAD TABLE* | No | Fatal firmware error on | Contact your authorized service |
|
|
| controller board. | representative.1 |
|
|
|
|
|
|
PAP BSY TOO LNG* | No | Fatal firmware error on | Contact authorized service |
|
|
| controller board. | representative.1 |
|
|
|
|
|
|
PAP FIFO OVERFL* | No | Fatal firmware error on | Contact your authorized service |
|
|
| controller board. | representative.1 |
|
|
|
|
|
|
PAP FIFO UNDRFL* | No | Fatal firmware error on | Contact your authorized service |
|
|
| controller board. | representative.1 |
|
|
|
|
|
|