3-5. Female Camlok Connector Assembly
12
1 in
(26 mm)
6
5
Tools Needed:
7/32 in
|
| 1 | Weld Input Cable |
|
| Strip insulation as shown. | |
|
| 2 | Copper Strip (Two Included) |
4 |
| 3 | Connector Body |
|
| Wrap strip around bare weld cable | |
|
| (use two on small diameter cable), | |
| 3 | and insert into connector body. | |
|
|
| |
|
| 4 | Setscrew |
Tighten setscrew against copper strip.
5Handle
6Pin
Slide handle over connector body so holes align; secure by tapping pin into place.
sb6.6* –
3-6. Male Camlok Connector Assembly
12
1 in
(26 mm)
6
5
1 Weld Output Cable
Strip insulation as shown.
2Copper Strip
3Connector Body
Wrap strip around bare weld cable
4(use two on small diameter cable), and insert into connector body.
4 Setscrew
3
Tighten setscrew against copper strip.
5Handle
6Pin
Slide handle over connector body so holes align; secure by tapping pin into place.
Tools Needed:
7/32 in
sb6.4* 11/92 –