5-16. Installing Ether Cylinder (Optional Ether Starting Aid)

1

2

3

4

5

6

YStop engine.

YImproper handling or expo- sure to ether can harm your health. Follow manufactur- er’s safety instructions on cylinder.

YDo not use Ether Starting Aid while engine is running.

Open right side door.

1Ether Cylinder

2Nozzle

Remove cover and clean cylinder nozzle.

3Clamp

4Fitting

5Cap

6Valve

Remove cap and clean fitting. Install cylinder on fitting. Tighten clamp.

.After installing cylinder, wait at

least 10 minutes before using to let ether particles settle and prevent atomizer plugging.

Put cap on fitting when cylinder is removed.

ether1 7/96 − 153 382-A / 190 377 / 802 291-A

5-17. Remote 14 Receptacle Information

NOTE

Place Welder Selector switch in Welder A/Welder B position (dual operator mode) for both remote receptacles to work. Welder A (left) remote receptacle output contactor and control is disabled when switch is in Welder B position.

 

Socket*

Socket Information

24 VOLTS AC

A

24 volts ac. Protected by circuit breakers CB5 and CB6.

 

B

Contact closure to A completes 24 volts ac contactor control circuit.

 

C

Output to remote control; +10 volts dc in CV, 0 to +10 volts dc in CC.

REMOTE

D

Remote control circuit common.

OUTPUT

CONTROL

E

0 to +10 volts dc input command signal from remote control.

 

A/V

F

Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes.

AMPERAGE

H

Voltage feedback; +1 volts dc per 10 arc volts.

VOLTAGE

 

 

115 VOLTS AC

I

115 volts, 15 amperes, 60 Hz ac. Protected by circuit breakers CB5 and CB6.

 

J

Contact closure to I completes 115 volts ac contactor control circuit.

 

K

Chassis common.

GND

G

Circuit common for 24 and 115 volts ac circuits.

 

*The remaining sockets are not used.