SECTION 6 − OPERATING THE WELDING GENERATOR

NOTE

When facing the front panel, the Welder B controls and weld terminals are on the right and the Welder A side controls and weld terminals are on the left.

6-1. Engine Controls

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

4

1

5

2

.See Section 6-3for weld control descriptions.

1Engine Start Button

2Manual Stop Control

3Ether Starting Aid Switch (Optional)

Push switch up and release while cranking engine to release ether.

To Start: Press button and use Ether switch (if necessary). Release button when engine starts.

.If the engine does not start, let engine

come to a complete stop before attempt- ing restart.

190 377

To Stop: Pull control out and hold. Release control when engine stops.

4 Battery Charging Warning Light

Light goes on when battery is not charging.

YIf light goes on, stop engine and check engine belt.

5 Engine Hour Meter