SLM-5650 Satellite Modem Revision 1
Remote Control MN/SLM5650.IOM
B3
B.5 Packet Structure
Controller-to-target:
Start of Packet Target Address Address
De-limiter Instruction
Code Code
Qualifier Optional
Arguments End of Packet
<
ASCII code 60
(1 character)
(4 characters)
/
ASCII code 47
(1 character)
(3 characters)
= or ?
ASCII code 61
or 63
(1 character)
(n characters)
Carriage Return
ASCII code 13
(1 character)
Example: <0135/TFQ=70.2345{CR}
Target-to-controller:
Start of Packet Target
Address Address
De-limiter Instruction
Code Code Qualifier Optional
Arguments End of Packet
>
ASCII
code 62
(1 character)
(4 characters)
/
ASCII
code 47
(1 character)
(3 characters)
=, ?, !, or *
ASCII code 61,
63, 33 or 42
(1 character)
(From 0 to n
characters)
Carriage Return,
Line Feed
ASCII code 13,10
(2 characters)
Example: >0654/RSW=32{CR}{LF}
Each of the components of the packet is now explained.
B.5.1 Start Of Packet
Controller to Target: This is the character ‘<’ (ASCII code 60)
Target to Controller: This is the character ‘>’ (ASCII code 62)
Because this is used to provide a reliable indication of the start of packet, these two
characters may not appear anywhere else within the body of the message.
B.5.2 Address
Up to 9999 devices can be uniquely addressed. In EIA-232 applications this value is set
to 0. In EIA-485 applications, the permissible range of values is 1 to 9999. It is
programmed into a target unit using the front panel keypad.