SLM-5650 Satellite Modem Revision 1
Remote Control MN/SLM5650.IOM
B–18
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Rx Clock
Invert RCI= 1 byte, value
of 0 or 1 Command or Query.
Invert Receive Clock, where:
x=Invert Receive Clock, where:
0=Normal
1=Inverted
Example: RCI=1 (selects Inverted RX Clock)
RCI =
RCI?
RCI*
RCI#
RCI? RCI=x
(see description of
arguments)
Rx Data Invert RDI= 1 byte, value
of 0 or 1 Command or Query.
Invert Receive Data, where:
x=Invert Receive Data, where:
0=Normal
1=Inverted
Example: RDI=1 (selects Inverted RX Data)
RDI =
RDI?
RDI*
RDI#
RDI? RDI=x
(see description of
arguments)
Rx Data Fault RDF= 1 byte, value
of 0 thru 2 Command or Query.
Receive Data Fault, where:
x= Receive Data Fault, where:
0=None
1=DATA
2=AIS
Example: RDF=0 (selects Data Fault = None)
RDF =
RDF?
RDF*
RDF#
RDF? RDF=x
(see description of
arguments)
Rx BPSK
Data Ordering RBO= 1 byte, value
of 0 or 1 Command or Query.
Invert Receive BPSK Data Ordering, where:
x=Invert Receive BPSK Data Ordering, where:
0=Normal
1=Inverted
Example: RBO=1 (selects Inverted BPSK Ordering)
RBO =
RBO?
RBO*
RBO#
RBO? RBO=x
(see description of
arguments)
Rx Demod
Acquisition
Sweep Range
RSW= 8 bytes Command or Query.
Rx acquisition sweep range of demodulator, in kHz, ranging from 0
to 60 kHz.
Example: RSW=0060.000 (selects 60 kHz)
RSW=
RSW?
RSW*
RSW#
RSW? RSW=xxxx.xxx
(see description of
arguments)