SLM-5650 Satellite Modem Revision 1
Remote Control MN/SLM5650.IOM
B–20
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
IP Address IPA= 18 bytes,
numerical Command or Query.
Used to set the IP address and network prefix for the
10/100 BaseTx Ethernet management port, in the format:
xxx.xxx.xxx.xxx.yy, where:
xxx.xxx.xxx.xxx is the IP address, and
yy is the network prefix (0-31)
Example: 010.006.030.001.24
IPA=
IPA?
IPA*
IPA#
IPA? IPA= xx.xxx.xxx.xxx.yy
(see description of
arguments)
Carrier Only
Test Modes COM= 1 byte, value
of 0 thru 2 Command or Query.
Test Mode, where:
0= Normal Mode (no test)
1=Tx CW
2=Tx Alternating 1,0 Pattern
Example: COM=1 (CW Mode)
COM=
COM?
COM*
COM#
COM? COM=x
(see description of
arguments)
Loopback
Test Modes LOP= 1 byte, value
of 0 thru 3 Command or Query.
Loopback Test Modes, where:
0=Normal Mode (no test)
1=IF Loopback
2=I/O Loopback #1
3=I/O Loopback #2
Example: LOP=1 (IF Loopback)
LOP=
LOP?
LOP*
LOP#
LOP? LOP=x
(see description of
arguments)
Tx BERT
State BTX= 1 byte, value
of 0 or 1 Command or Query.
Tx BERT State, where:
0=Off
1=On
Example: BTX=1 (Tx BERT On)
BTX=
BTX?
BTX*
BTX#
BTX? BTX=x
(see description of
arguments)
Rx BERT
State BRX= 1 byte, value
of 0 or 1 Command or Query.
Rx BERT State, where:
0=Off
1=On
Example: BRX=1 (Rx BERT On)
BRX=
BRX?
BRX*
BRX#
BRX? BRX=x
(see description of
arguments)