SLM-5650 Satellite Modem Revision 1
Remote Control MN/SLM5650.IOM
B–13
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Tx Clock
Invert TCI= 1 byte, value
of 0 or 1 Command or Query.
Invert Transmit Clock, where:
x=Invert Transmit Clock, where:
0=Normal
1=Inverted
Example: TCI=1 (selects Inverted TX Clock)
TCI =
TCI?
TCI*
TCI#
TCI? TCI=x
(see description of
arguments)
Tx Data Invert TDI= 1 byte, value
of 0 or 1 Command or Query.
Invert Transmit Data, where:
x=Invert Transmit Data, where:
0=Normal
1=Inverted
Example: TDI=1 (selects Inverted TX Data)
TDI =
TDI?
TDI*
TDI#
TDI? TDI=x
(see description of
arguments)
Tx Data Fault TDF= 1 byte, value
of 0 thru 2 Command or Query.
Transmit Data Fault, where:
x=Transmit Data Fault, where:
0=None
1=DATA
2=AIS
Example: TDF=0 (selects Data Fault = None)
TDF =
TDF?
TDF*
TDF#
TDF? TDF=x
(see description of
arguments)
Tx BPSK
Data Ordering TBO= 1 byte, value
of 0 or 1 Command or Query.
Invert Transmit BPSK Data Ordering, where:
x=Invert Transmit BPSK Data Ordering, where:
0=Normal
1=Inverted
Example: TBO=1 (selects Inverted BPSK Ordering)
TBO =
TBO?
TBO*
TBO#
TBO? TBO=x
(see description of
arguments)