SLM-5650 Satellite Modem Revision 1
Remote Control MN/SLM5650.IOM
B–12
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Tx Differential
Encoding TDE= 1 byte Command or Query.
Tx Differential Encoding, where:
x=Tx Differential Encoding, where:
0=Off
1=On
Depending on FEC type or Modulation Type, not all of these
selections will be valid.
Example: TDE=1 (selects Tx Differential Encoding On)
TDE=
TDE?
TDE*
TDE#
TDE? TDE=x
(see description of
arguments)
Tx Power
Level TPL= 5 bytes Command or Query.
Tx Output power level, where:
s=sign ( + / - )
xx.x = Tx Output power level, +10.0 and –40.0 dBm.
Example: TPL=-13.4
TPL=
TPL?
TPL*
TPL#
TPL?
TPL=sxx.x
(see description of
arguments)
Tx Clock
Source TCK= 1 byte Command or Query.
Tx Clock Source, where:
x=Tx Clock Source, where:
0=Internal
1=Tx Terrestrial
Example: TCK=1 (selects Tx Terrestrial Clock Source)
TCK=
TCK?
TCK*
TCK#
TCK? TCK=x
(see description of
arguments)
Tx SCT
Reference SCT= 1 byte, valu e
of 0 thru 2 Command or Query.
SCT Clock Reference, where:
x=SCT Clock Reference, where:
0=Internal
1=Data Source Synchronized
2=Rx-Satellite Clock
Example: SCT=0 (selects Internal Modem Reference)
SCT =
SCT?
SCT*
SCT#
SCT? SCT=x
(see description of
arguments)