Monessen Hearth IDV490PVC manual Check Gas Pressure, Do not use open flame to, check for gas leaks

Models: IDV380NVC IDV490NVC IDV380PVC IDV490PVC

1 40
Download 40 pages 56.07 Kb
Page 17
Image 17
CHECK GAS PRESSURE

CHECK GAS PRESSURE

IDV380/IDV490 Fireplace Insert

1.Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately.

2.Install and attach flex line provided on this appliance to 1/2" gas line.

3.After completing gas line connection, purge air from gas line and test all gas joints from the gas meter to the fireplace for leaks. Use a soap and water solution or a gas sniffer.

4.To adjust flame height, turn HI/LO knob to HI to get maximum pressure to burner. Turn HI/LO knob to LO to get minimum pressure.

5.To check gas pressures at valve, turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point. Turn unit to high. Figure 16. After taking pressure reading, be sure and turn captured screw clock- wise firmly to reseal. Do not over torque. Check test points for gas leaks with a soap and water solution or an electronic gas leak detector.

WARNING

Do not use open flame to

 

 

check for gas leaks.

 

 

Pressure

Test "IN"

Pressure Test "OUT"

HI/LO Knob

Pilot Adjustment Screw

 

Figure 16 -

Gas Pressure Check at Gas Valve

FP1932

57D0016

17

Page 17
Image 17
Monessen Hearth IDV490PVC, IDV490NVC, IDV380NVC Check Gas Pressure, Do not use open flame to, check for gas leaks, 57D0016