OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

IDV380/IDV490 Fireplace Insert

approved leak testing method Lighting pilot for the first time danger

approved leak testing method

You may check for gas leaks with the following meth- ods only:

Soap and water solution

An approved leak testing spray

Electronic sniffer

WARNING

If using a soap and water solution to test for leaks, DO NOT spray solution onto control body.

danger
Never check for gas leak with open flame!

NOTE: Remove any excessive pipe compound from the connections. Excessive pipe compound can set off electronic sniffers.

Check for gas leaks in each of the following locations:

Pipe from the gas supply line connection to the gas valve

Burner connections

• Field made joints / gas shutoff valve

Pilot

Factory made joints

Each joint or connection

All joints on valve and control body

WARNING

Lighting pilotNever check for gas leak with open flame!

The control has an interlock device that does not allow the lighting of the fireplace up to the moment the safety device of the flame has not interrupted the gas flow. After that period of time (when the magnet is closed), it is possible to start the lighting operation.

The gas control knob is designed to be operated by hand. DO NOT use any tools during this operation. Damaged knobs may result in serious injury.

1.Depress and turn knob counterclockwise Lighting pilot to pilot position.

2.Depress fully and hold pilot gas knob. Depress piezoigniterasmanytimesasneededtoignitepilot. Keep knob fully depressed for a few seconds. Release and check that pilot continues to burn.

If the pilot does not stay lit,

WARNING

If the knob does not "pop"

out to its original position
repeat steps 1 and 2.
when released, turn off gas

 

 

to appliance and contact

 

qualified service technician.

 

 

 

 

O

T

N

O

 

L

 

I

 

P

 

 

F

 

F

 

O

PILOT

Figure 32 - Pilot Position