BLOWER REMOVAL and ASSEMBLY |
| IDV380/IDV490 Fireplace Insert | |||
BLOWER PARTS LIST: |
|
|
|
|
|
|
|
|
|
|
|
Description |
| qty. |
| Part No. |
|
Blower |
| 1 |
| 26D0748 |
|
| Parts not shown |
|
| ||
Thermostat Bracket |
| 1 |
| 26D3320 |
|
Thermostat |
| 1 |
| 49D0130 |
|
Speed Control |
| 1 |
| 26D0746 |
|
Wire Harness |
| 1 |
| 41D0203 |
|
|
|
|
|
|
|
CAUTION
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
| Variable | Blower |
| Speed | |
| Snap | |
| 1 Control 2 | |
| Disc | |
OFF | ON |
|
|
|
110/115 V AC |
|
|
|
|
|
|
|
|
|
| White | ||||||||||
|
|
|
|
|
|
|
|
|
| (Hi Temp) | |||||||||||
Blower Plug |
|
|
| Black |
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
| White |
|
|
|
|
|
|
| Blower | |||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
| Green |
|
|
|
|
|
|
| Motor | |||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| FP1946 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTE: Unplug power cord before servicing. The blowers are attached to insert bottom and back with Velcro. To remove blower for servicing, pull away from Velcro and
disconnect wires.
57D0016 | 33 |