Monessen Hearth IDV380PVC Venting installation, Installation Precautions, common vent systems

Models: IDV380NVC IDV490NVC IDV380PVC IDV490PVC

1 40
Download 40 pages 56.07 Kb
Page 11
Image 11
Venting installation

Venting installation

 

 

Read all instructions completely and

 

WARNING

thoroughly before attempting installation.

 

Failure to do so could result in serious

 

 

 

 

injury, property damage or loss of life.

 

 

Operation of improperly installed and

 

 

maintained venting system could result in

 

 

serious injury, property damage or loss of

 

 

life.

 

 

 

 

 

 

 

NOTICE

Failure to follow these instructions will

 

 

 

 

void the warranty.

 

 

 

INSTALLATION PRECAUTIONS

Consult local building codes before beginning the instal- lation. The installer must make sure to select the proper vent system for installation. Before installing vent kit, the installer must read this insert manual and vent kit instructions.

Only a qualified installer/service person should install venting system. The installer must follow these safety rules:

Wear gloves and safety glasses for protection.

Use extreme caution when using ladders or when on rooftops.

Be aware of electrical wiring locations in walls and ceiling.

The following actions will void the warranty on your vent- ing system:

Installation of any damaged venting component.

Unauthorized modification of the venting system.

Installation of any component part not manufac- tured or approved by MHSC.

Installation other than permitted by these instruc- tions.

 

This insert must be vented to the

WARNING

outside. The venting system must

NEVER be attached to a chimney

 

 

serving a separate solid fuel burning

 

appliance. Each gas appliance must

 

use a separate vent system. Do not use

 

common vent systems.

 

 

IDV380/IDV490 Fireplace Insert

VENTING REQUIREMENTS

 

WARNING

Make sure the exhaust pipe on heater

 

connects to exhaust portion of cap. At-

 

 

 

 

tach flex liners. Figure 6

 

 

Do not crimp or rupture liner when bend-

 

 

ing it into chimney offsets.

 

 

 

The exhaust vent must reline the entire length of chimney and terminate above chimney top.

Vent must meet all vent manufacturer's requirements when installed.

Make sure you have the following before installing unit:

380 Series:

3" and 3" UL 1777 Listed gas liner for air inlet and exhaust.

Vertical termination kit (AI31TK33A)

490 Series:

4" and 3" UL 1777 Listed gas liner for air inlet and exhaust.

Vertical termination kit (AI42TK43A)

Maximum

Height

40' (12.9 m) Inlet INSTALLATION PRECAUTIONS Exhaust Minimum

Height

10' (3 m)

This insert must be vented to theoutside. The venting system must Maximum 12"

(305 mm) Offset at

Base of Insert

FP2625

Figure 7 -

Venting Unit

57D0016

11

Page 11