Monessen Hearth KHLDV SERIES Pre-Installationinformation, INSTALLING ABOVE 2000 FEET, Natural Gas

Models: KHLDV SERIES

1 52
Download 52 pages 49.7 Kb
Page 6
Image 6
PRE-INSTALLATION INFORMATION

PRE-INSTALLATION INFORMATION

INSTALLING ABOVE 2000 FEET

In the USA, the appliance must be derated 4% for every 1,000 ft above 2,000 ft elevations. Where the heating value of the gas has been reduced, these rules do not apply.

In Canada, these appliances are certified for altitudes of 0 – 2000 ft, and must be de-rated by 10 percent for installations between 2000 and 4,500 ft. (derate an additional 4% for every 1,000 ft. above 4,500 ft. elevations).

ORIFICE SIZES, PRESSURES AND BTUs

NATURAL GAS

 

PROPANE GAS

 

Manifold Press: (W.C.)

3.5"

Manifold Press: (W.C.)

10"

Maximum Supply Pressure

10.5"

Maximum Supply Pressure

13"

Minimum Supply Pressure

4.5"

Minimum Supply Pressure

11"

Model Number

KHLDV400

KHLDV500

Gas Type

Natural

Propane

Natural

Propane

 

 

 

 

 

Max. Btu/hr Input

40,000

40,000

50,000

50,000

 

 

 

 

 

Min. Btu/hr Input

28,500

30,500

35,500

38,500

 

 

 

 

 

Rear Orifice Size

#35 (.110")

#52 (.0635")

#30 (.1285")

#50 (.070")

 

 

 

 

 

Front Orifice Size

#49 (.073")

#56 (.0465")

2.3 mm

#55 (.052")

 

 

 

 

 

BEFORE YOU START

Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts. Check your packing list to verify that all listed parts have been received. You should have the following:

Fireplace (Firebox and Burner System)

Rock Wool

Log Set

ITEMS REQUIRED FOR INSTALLATION

 

 

Tools:

Building Supplies:

Phillips Screwdriver

Framing materials

Hammer

Wall finishing materials

• Saw and/or saber saw

Non-combustible finishing material or dura-rock*

Pipe Wrench

Caulking material (non-combustible)

Level

• Fireplace surround material (non-combustible)

Measuring Tape

• Piping complying with local codes

• Electric Drill and Bits

Tee joint

Pliers

• Pipe sealant approved for use with propane/LPG

Square

 

(resistant to sulfur compounds)

*Only used if desired to cover painted face other than using tiles or marble. If tiles or marble are used around the face then the non-combustible material is not needed.

6

73D0024

Page 6
Image 6
Monessen Hearth KHLDV SERIES Pre-Installationinformation, INSTALLING ABOVE 2000 FEET, ORIFICE SIZES, PRESSURES AND BTUs