Hardware Configuration
The SMC controller card contains the CY 545 motion controller, EEprom memory, memory latches (2 each),
Serial Format
The SMC is connected as a
During operation from memory or when homing, the CTS function is not 100% busy; pulses on/off each instruction. This is to allow interruption of routines by the host computer sending a stop command (0 or CR). If other data is sent, incorrect operation will result. To set the SMC 100% busy during operations: (1) disable the CTS function with the Mode command. User Bit 6 will set HI or busy. (2) As the last instruction, in the memory routine,
NOTE: | the correct Mode command to defeat the CTS is: o 080h. |
| the correct Mode command to enable the CTS is: o 0a0h |
| (Any hex value starting with a letter must be preceded by a zero) |
Memory Format. The memory is configured as 2K bytes of EEPROM (RAM is optional). It is not possible to access memory above address 2047. Note that the memory is in pages of 256 bytes; the CY545 does not allow Jump, Test, or Loop operations across page boundries. The pointer command (Y) is used to move across boundries. A feature of the 545 memory system, the Auto- Start function which recognizes special character flags in the first bytes of memory as a command to run the following program at
Home Function. This system uses an optical sensor to establish the starting reference or "Home" position at
Limit Loop Function. The