d 09: Upstream Modem (STARVUE II Diagnostics)
This diagnostic shows the status and operating parameters for the STARVUE II RF return.
Figure B-10
STARVUE II Diagnostic
09 STARVUE II DIAGNOSTICS
STATUS: DISABLED
FREQUENCY: 23.000 MHz
LEVEL: 39
IPPV: DISABLED
LAST POLL REQ: 170
6-15-2001 20:49:33
LAST POLL ACK: 170
6-15-2001 20:49:33
Table B-11
STARVUE II Transmitter Fields
Field Description
Status Indicates the transmitter status with the following variables:
- Idle
t Transmitting
Frequency Indicates the transmitting frequency.
Level Indicates the approximate power value of the STARVUE II transmitter in dBmV. The
difference between the power value on the diagnostic screen and the actual power of
the STARVUE II module may be ± 5 dBmV.
IPPV Indicates the Interactive Pay-Per-View status with the following variables:
ENABLED IPPV enabled
UNSENT
##
The set-top contains unsent IPPV transactions. The variable
## is the
number of unsent transactions.
DISABLED IPPV disabled
Last Poll Req. Indicates the sequence number of the last poll request received by the set-top. The
time stamp of the last poll request is displayed under LAST POLL REQ:
! If the set-top has received no poll request, , the sequence number and time stamp
fields display N/A.
! If the set-top has received a poll request set-top but its system time has not yet
been initialized, the time stamp field displays NOT AVAILABLE.
Last Poll Ack. Indicates the sequence number of the last poll acknowledge received by the set-top.
The time stamp of the last poll acknowledge is displayed under LAST POLL ACK.
! If the set-top has received no poll acknowledge, the sequence number and time
stamp fields display N/A.
! If the set-top has received a poll acknowledge but its system time has not yet been
initialized, the time stamp field displays NOT AVAILABLE.