3.2 Quick Start 3 Diagnostic Programs
TECRA S1Maintenance Manual 3
3.2 Quick Start
Boot from Service Diagnostic CD, the following screen will be displayed:
Please select a test item or select 9 to exit to MS-DOS:
3.2.1 Quick Test
When this item selected, system will run the configured test items and generate a test report
automatically.
When the test completes, a file named Quick.log would be saved in the defined location.
For the backup purpose of the log file, system will automatically rename Quick.log to
Quick.old when Quick.log is created and there is already a file quick.log existed.
Testing all items will take 8-15 minutes. User must plug the COM Test Fixture & LPT Text
Fixture before testing. During the testing, user is required to verify the test result.
The detail of test item please reference Quick Test Item List.
3.2.2 Customization Test
When this item selected, system will run the diagnostic programs according to the procedures
you defined. When the test complete, a file named Custom.log will be saved in the defined
location Please see the following example-- Mouse test.
1. Use arrow key to select ‘PS2 Mouse’ item on ‘Peripheral’ in the menu, then press Space
key to select it. (When selected, there is a X marked in the [ ])