2 Troubleshooting | 2.3 Power Supply |
Procedure 2 Connection Check
Power is supplied to the system board as illustrated below:
AC
adaptor
AC power cord | AC adaptor cord |
System board
Battery pack
Follow the steps below to check whether each connector has been connected correctly: Check 1 Make sure the AC adaptor and AC power cord have been firmly plugged into
the DC IN 15V socket and wall outlet, respectively. When they have been connected correctly, perform Check 2.
Check 2 Connect a new AC adaptor and AC power cord.
•If the DC IN LED does not go on, go to Procedure 3.
•If the battery LED does not go on, perform Check 3.
Check 3 Make sure the battery pack has been correctly installed in the computer. If the battery LED does not go on while the battery pack has been installed correctly, go to Procedure 3.
TECRA S1 Maintenance Manual |