2 Troubleshooting

 

2.4 System Board

 

 

Table 2-2

Printer port LED boot mode status (3/3)

 

 

 

 

 

 

LED Status

Test Item

 

Description

 

(Hexadecimal)

 

 

 

 

 

 

40H

DEBUG_CS_CONFIG_PORTS

Configure the COMM and LPT ports

 

41H

DEBUG_FLOP_INIT

 

According cmos data to initialize the floppies

 

42H

DEBUG_WINI_INIT

 

Scan and initialize the hard disk, and display the result

 

 

 

 

on crt

 

43H

DEBUG_HWIO_ROM_INIT

Search option rom from c800 to e000 and to Initialize

 

 

 

 

option ROMs

 

44H

DEBUG_OEM_INIT_POWER_MAN

Check special device initial power management function

 

45H

DEBUG_KEYB_SET_LEDS_2

Clear keyboard buffer and Update NUMLOCK status

 

46H

DEBUG_HWIO_FIND_80X87

Test For Coprocessor Installed,and enable

 

 

 

 

coprocessor interrupt

 

47H

DEBUG_OEM_LAST_MINUTE_INIT

Run OEM functions before boot, and enable

 

 

 

 

L1,L2 cache

 

48H

DEBUG_MISC_LAUNCH_INT19

Post code will finish,ready to run int19

 

 

 

 

and load OS

 

49H

DEBUG_BEGIN_BOOT_CODE

Into Int19, to boot from floppy or other

 

 

 

 

boot device

 

50H

DEBUG_ACPI_INIT

 

Initialize the ACPI function

 

51H

DEBUG_PM_CPU_INIT

 

Power manager initial & GEYSERVILLE CPU

 

 

 

 

initialize

 

52H

DEBUG_USB_HC_INIT

 

Clear USB status register and Initiallize

 

 

 

 

the USB Hub controllor

2-16

TECRA S1 Maintenance Manual

Page 53
Image 53
Toshiba TECRA S1 manual Printer port LED boot mode status 3/3, Description