2 – QCP2330/2332 FCode

The new connection mode displays. For example:

Calculating NVRAM checksum, please wait...

Current HBA connection mode: 0 - Loop Only

Possible connection mode choices: 0 - Loop Only

1- Point-to-point only

2- Loop preferred, otherwise point-to-point

2.4.3

Setting the QCP2330/2332 HBA Loop ID

When the QCP2330/2332 HBA is currently operating in loop mode (through connection mode 0 or connection mode 2), perform the following steps to view its loop ID and change it if necessary:

1. To view the loop ID, type the show-adapter-loopidcommand.

ok show-adapter-loopid

The loop ID displays. For example:

Adapter loopid - 7c

2.If the loop ID is not correct, change it using the set-adapter-loopidcommand. For example:

ok 0 set-adapter-loopid

The new loop ID displays. For example:

Adapter loopid - 0

2.4.4

Selecting the Boot Device

Perform the following steps to select a Fibre Channel device that is attached to the QCP2330/2332 HBA as the boot device:

1.Use the show-devscommand to display the device tree for all devices attached to the machine.

ok show-devs

The device tree displays. The QCP2330/2332 HBAs with FCode are referenced with QLGC,qla@. For example:

ok show-devs

.

.

/pci@1f,0/pci@1/QLGC,qla@4

CF2351102-00 F

2-7

Page 17
Image 17