Q-Logic 2300 series manual Setting the QCP2340/2342 HBA Loop ID

Models: 2300 series

1 62
Download 62 pages 6.02 Kb
Page 32
Image 32

3 – QCP2340/2342 FCode

Q

The connection mode and options display. For example:

Current HBA connection mode: 2 - Point-to-point only

Possible connection mode choices: 0 - Loop Only

1- Point-to-point only

2- Loop preferred, otherwise point-to-point

2.If the connection mode is not correct based on the devices connected to the QCP2340/2342 HBA, change it using the set-connection-modecommand. For example:

ok 0 set-connection-mode

The new connection mode displays. For example:

Calculating NVRAM checksum, please wait...

Current HBA connection mode: 0 - Loop Only

Possible connection mode choices: 0 - Loop Only

1- Point-to-point only

2- Loop preferred, otherwise point-to-point

3.4.3

Setting the QCP2340/2342 HBA Loop ID

When the QCP2340/2342 HBA is currently operating in loop mode (through connection mode 0 or connection mode 2), perform the following steps to view its loop ID and change it if necessary:

1. To view the loop ID, type the show-adapter-loopidcommand.

ok show-adapter-loopid

The loop ID displays. For example:

Adapter loopid - 7c

2.If the loop ID is not correct, change it using the set-adapter-loopidcommand. For example:

ok 0 set-adapter-loopid

The new loop ID displays. For example:

Adapter loopid - 0

3-8

CF2351102-00 F

Page 32
Image 32
Q-Logic 2300 series manual Setting the QCP2340/2342 HBA Loop ID, Connection mode and options display. For example