2 – QCP2330/2332 FCode

Q

3.Set the QCP2330/2332 HBA loop ID (see section 2.4.3).

4.Select the boot device (see section 2.4.4).

5.Build the bootable disk (see section 2.4.5).

2.4.1

Updating FCode on the QCP2330/2332 HBA

If you need to update the FCode on the QCP2330/2332 HBA, use the QLogic qla2x00 flash utility. A QLogic Solaris SPARC driver revision 3.06 or later must be installed before the flash utility can be run.

WARNING!! Be very careful when changing flash contents; incorrect data may render the QCP2330/2332 HBA unusable to the point that the operating system may no longer function.

Perform the following steps to run the flash utility:

1.Copy the qla2x00flash file and the ifp2300.prom file to the desired directory.

2.At the command line, enter the appropriate path. Use the information obtained with the show-devscommand (see step 1 in section 2.4.4). For example:

./qla2x00flash -l /devices/pci@1f,0/pci@1/QLGC,qla@4: devctl ifp2300.prom

2.4.2

Setting the QCP2330/2332 HBA Connection Mode

Perform the following steps to view the current QCP2330/2332 HBA connection mode and change it if necessary:

1.To view the current connection mode, type the show-connection-modecommand:

ok show-connection-mode

The connection mode and options display. For example:

Current HBA connection mode: 1 - Point-to-point only

Possible connection mode choices: 0 - Loop Only

1- Point-to-point only

2- Loop preferred, otherwise point-to-point

2.If the connection mode is not correct based on the devices connected to the QCP2330/2332 HBA, change it using the set-connection-modecommand. For example:

ok 0 set-connection-mode

2-6

CF2351102-00 F

Page 16
Image 16