4 Replacement Procedures 4.16 FL Inverter Board
4-56 TECRA S1 Maintenance Manual
3. Disconnect the HV cable from CN2 and remove the FL inverter board.
Figure 4-37 Disconnecting the cables
Installing the FL Inverter Board
Install the FL inverter board according to the following procedures and Figures 4-36 and 4-
37.
1. Connect the LCD/FL cable to CN1, and connect the HV cable to CN2.
2. Place the FL inverter board in the correct position.
3. Fasten the M2x3 white bind screw to secure the FL inverter board.