Motorola IOT Command Parameters for Supported Floppy Types, MVME166IG/D2, IOT Parameter, DSDD5

Models: MVME166IG MVME166D2 MVME166IG/D2

1 122
Download 122 pages 34.03 Kb
Page 113
Image 113
IOT Command Parameters for Supported Floppy Types

IOT Command Parameters for Supported Floppy Types

 

IOT Command Parameters for Supported Floppy Types

B

 

The following table lists the proper IOT command parameters for floppies

 

used with boards such as the MVME328, MVME166, and MVME187.

 

 

 

 

Floppy Types and Formats

 

 

IOT Parameter

 

 

 

 

 

 

 

DSDD5

PCXT8

PCXT9

PCXT9_3

PCAT

PS2

SHD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sector Size

 

 

 

 

 

 

 

0- 128 1- 256 2- 512

 

 

 

 

 

 

 

3-1024 4-2048 5-4096 =

1

2

2

2

2

2

2

 

 

 

 

 

 

 

 

Block Size:

 

 

 

 

 

 

 

0- 128 1- 256 2- 512

 

 

 

 

 

 

 

3-1024 4-2048 5-4096 =

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

Sectors/Track

10

8

9

9

F

12

24

 

 

 

 

 

 

 

 

Number of Heads =

2

2

2

2

2

2

2

 

 

 

 

 

 

 

 

Number of Cylinders =

50

28

28

50

50

50

50

 

 

 

 

 

 

 

 

Precomp. Cylinder =

50

28

28

50

50

50

50

 

 

 

 

 

 

 

 

Reduced Write Current

50

28

28

50

50

50

50

Cylinder =

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Step Rate Code =

0

0

0

0

0

0

0

 

 

 

 

 

 

 

 

Single/Double DATA

D

D

D

D

D

D

D

Density =

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single/Double TRACK

D

D

D

D

D

D

D

Density =

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single/Equal_in_all Track

S

E

E

E

E

E

E

Zero Density =

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slow/Fast Data Rate =

S

S

S

S

F

F

F

 

 

 

 

 

 

 

 

Other Characteristics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of Physical Sectors

0A00

0280

02D0

05A0

0960

0B40

1680

 

 

 

 

 

 

 

 

Number of Logical Blocks

09F8

0500

05A0

0B40

12C0

1680

2D00

(100 in size)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of Bytes in Decimal

653312

327680

368460

737280

1228800

1474560

2949120

 

 

 

 

 

 

 

 

Media Size/Density

5.25/DD

5.25/DD

5.25/DD

3.5/DD

5.25/HD

3.5/HD

3.5/ED

 

 

 

 

 

 

 

 

NOTES: 1. All numerical parameters are in hexadecimal unless otherwise noted.

2. The DSDD5 type floppy is the default setting for the debugger.

MVME166IG/D2

B-5

Page 113
Image 113
Motorola manual IOT Command Parameters for Supported Floppy Types, MVME166IG/D2, Floppy Types and Formats, IOT Parameter