Wand Emulation Interface 9 - 7
Convert All Bar Codes to Code 39
By default, the Wand Emulation interface sends data to the attached host in the s ame symbology that was
decoded. This can present a problem for customers with older systems that do not recognize some newer
symbologies (for example, GS1 DataBar).
Enable this parameter to ignore the decoded symbology, and output the data as Code 39. Lowercase characters in
the original data stream transmit as uppercase. This also allows ADF formatting.
Enable Ignore Unknown Characters to replace any characters that do not have a corresponding character in the
Code 39 symbology with a space.
If you disable Ignore Unknown Characters, when the scanner encounters characters that do not have a
corresponding character, it emits an error beep and discards the data.
Enable Convert to Code 39 for Wand Host
*Disable Convert to Code 39 for Wand Host
Convert Code 39 to Full ASCII
By default, a space replaces any characters that do not have a corresponding character in the Code 39 sy mbology
set. Enable this parameter to encode the data sent to the Wand inter face in Code 39 Full ASCII. In order to do this,
the host must be able to interpret Code 39 Full ASCII data.
This setting applies only if you enabled Convert to Code 39.
*Disable Code 39 Full ASCII Conversion
Enable Code 39 Full ASCII Conversion
NOTE ADF Note: By default, the Wand Emulation interface does not allow ADF rules to pr ocess
scanned data. Enabling this parameter allows ADF rules to proc ess scanned data. See Chapter