Web Console Configuration

Click on the Modify button to open the Modify time settings window to input the correct local time.

Time server

Setting

Factory Default

Necessity

IP or Domain address

None

Optional

(E.g., 192.168.1.1 or time.stdtime.gov.tw

 

 

or time.nist.gov)

 

 

NPort 5410/5430/5340I uses SNTP (RFC-1769) for auto time calibration.

Input the correct “Time Server” IP address or domain address. Once NPort is configured with the correct Time Server address, NPort will request time information from the “Time Server” every 10 minutes.

Console

The “Disable” option for Web Console and Telnet Console is included for security reasons. In some cases, you may want to Disable one or both of these Console utilities as an extra precaution to prevent unauthorized users from accessing your NPort. The factory default for both Web Console and Telnet Console is Enable.

Setting

Factory Default

Necessity

Enable or Disable

Enable

Required

 

 

 

If you disable both the “Web Console” and “Telnet Console,” you can still use the LCM Display to configure NPort locally, or Windows Administrator to configure NPort either locally or remotely over the network.

Network Settings

NPort 5400 Series User’s Manual 5-5

Page 31
Image 31
Moxa Technologies 5400 user manual Network Settings, Console, Time server, Setting Factory Default Necessity