Web Console Configuration
Click on the Modify button to open the Modify time settings window to input the correct local time.
Time server
Setting | Factory Default | Necessity |
IP or Domain address | None | Optional |
(E.g., 192.168.1.1 or time.stdtime.gov.tw |
|
|
or time.nist.gov) |
|
|
NPort 5410/5430/5340I uses SNTP
Input the correct “Time Server” IP address or domain address. Once NPort is configured with the correct Time Server address, NPort will request time information from the “Time Server” every 10 minutes.
Console
The “Disable” option for Web Console and Telnet Console is included for security reasons. In some cases, you may want to Disable one or both of these Console utilities as an extra precaution to prevent unauthorized users from accessing your NPort. The factory default for both Web Console and Telnet Console is Enable.
Setting | Factory Default | Necessity |
Enable or Disable | Enable | Required |
|
|
|
If you disable both the “Web Console” and “Telnet Console,” you can still use the LCM Display to configure NPort locally, or Windows Administrator to configure NPort either locally or remotely over the network.