Multi-Tech Systems ISI4608-PCI SCO Open Server 5 Driver Installation, Removing the Driver Novell

Models: ISI4608-PCI

1 70
Download 70 pages 53.2 Kb
Page 37
Image 37

Chapter 3—Software/Driver Installation

f:\system\aio\directory. Click Yes to overwrite the existing aiomdms.mdc file.

Configuring Ports for NetWare Connect

When the driver is installed, it will allocate consecutive ports for the ISI card as follows:

8 consecutive ports for the ISI4608-PCI.

4 consecutive ports for the ISI4604-PCI.

To set up NetWare Connect ports, enter LOAD NWCCON at the NetWare console prompt. LOAD NWCCON opens the NetWare Connect Configuration Utility. Select the appropriate menu options (modem type, speed, flow control, etc.).

Removing the Driver (Novell)

In Novell, remove file AIOISIX.NLM from the system directory and make the appropriate changes to the Autoexec.ncf file.

SCO Open Server 5 Driver Installation

The ISI driver for SCO Open Server 5 is shipped on CD-ROM (FAT file system) and can also be downloaded from the Multi-Tech web site. In both cases, the driver files are compressed (“tarred”). Users installing from the CD-ROM should begin at “To install from CD-ROM” directly below. Users installing from a floppy disk should skip down to “To install driver from floppy disk” later in this section. The filename of the SCO5 driver in its tarred form is isisco.tar.

This present installation section is task-oriented with minimal explanation of procedural steps. The section Multi-Tech Installation Script, which immediately follows this section, presents additional details to aid in installation.

To install from CD-ROM:

# mount -r /dev/cd0 /mnt

37

Page 37
Image 37
Multi-Tech Systems ISI4608-PCI manual SCO Open Server 5 Driver Installation, Configuring Ports for NetWare Connect