Hardware Preparation and Installation

2.7Completing the Installation

The board is designed to operate as an application-specific computer blade or an intelligent I/O board/carrier. It can be used in any slot in a VME chassis. Once the board is installed, you are ready to connect peripherals and apply power to the board.

Product Damage

RJ-45 connectors on modules are either twisted-pair Ethernet (TPE) or E1/T1/J1 network interfaces. Connecting an E1/T1/J1 line to an Ethernet connector may damage your system.

Make sure that TPE connectors near your working area are clearly marked as network connectors.

Verify that the length of an electric cable connected to a TPE bushing does not exceed 100 meters.

Make sure the TPE bushing of the system is connected only to safety extra low voltage circuits (SELV circuits).

If in doubt, ask your system administrator.

The console settings for the MVME2500 are:

Eight bits per character

One stop bit per character

Parity disabled (no parity)

Baud rate of 9600 baud

Verify that hardware is installed and the power/peripheral cables connected are appropriate for your system configuration.

Replace the chassis or system cover, reconnect the chassis to power source, and turn the equipment power on.

34

MVME2500 Installation and Use (6806800L01H)

Page 34
Image 34